Disaster Simulation
The DR test restores the server into the Sefthy cloud in an isolated environment for up to three hours, with no effect on the production server. Requirements, starting, ending and how it differs from the automatic test.
The DR test restores the protected server into the Sefthy cloud as in a real DR, but in an isolated environment. The test machine is created isolated from the network, so the original server keeps working and running its backups while you verify that the copy starts.
The number of tests is limited. Sefthy PRO includes 4 per month, Sefthy 1. The counter resets on the first day of each month.
Anteprima video temporaneamente non disponibile.
Apri il file direttamente →Starting the DR test
- Open the DR page and click Start DR Test in the action bar at the top, the button with the test tube.
- The confirmation box shows how many tests you have left out of the ones available, and that the machine will stay up for a maximum of 3 hours. Confirm to continue.
- The status band on the page turns to Preparing DR while Sefthy prepares the machine in the cloud. If the status stays on this phase for a long time, reload the page.
- When Restoring appears, pick the recovery point in the three steps Day, Snapshot and Disks, then click Start Recovery.
- Once the restore is done the page shows a confirmation and Open remote console appears. From the remote console you access the machine as if you were at the screen and check that the services respond.
The calendar shows the snapshots still within your plan retention, 30 days on Sefthy and 45 on Sefthy PRO.
Ending the DR test
After 3 hours the test machine is deleted automatically and the DR goes back to its protected state. If you finish your checks sooner, close the test with End DR Test from the same page.
The test still counts, even if you close it after a few minutes.
Manual test and automatic test
You start the DR test yourself, when you want to verify the restart directly. In parallel, on the Sefthy and Sefthy PRO plans, Sefthy automatically runs a control restore and produces a report about it. The two are independent and do not affect each other. The automatic test is covered in The automatic restore test and its report.